Aging chamber for rubber xenon lamps

Rubber xenon lamp aging boxThe working principle is to carry out comprehensive weather resistance test equipment, after adding light aging to the temperature and humidity, ambient climate, xenon lamp ratio are more comprehensive the conditions of the ultraviolet simulation: it simulates the full spectrum, which is particularly suitable for some automotive interior and paint products, and xenon lamps are usually used for standard-compliant product testing.


Technical parameters of xenon rubber lamp aging box:

model

Studio size

D*W*H(mm)

Dimensions

D*W*Hmm

Temperature and humidity range

Light source

Power supply 50HZ/total rate

LQ-XD1

500*500*400

based on actual size

Temperature 0 ~ 80℃/RT+10-70℃

humidity 30~98%R•H

Longarc Xenon Lamp

1.8~6KW optional

380V/6.5KW

LQ-XD2

600*500*500

The actual size is the default size

380V/7.5KW

LQ-XD3

750* 600 *500

based on actual size

380V/8.5KW

LQ-XD4

800*800*800

based on actual size

380V/9KW

Xenon lamp cooling (air cooling):

1. The powerful centrifugal fan provides a good cooling environment for the lamp tube and prolongs its service life.

2. Add an independent xenon lamp temperature probe to avoid abnormal situations and protect the lamp tube in time.

3. Xenon lamp cooling air duct, low exhaust resistance, high reflection efficiency.

4. Independent space design, easy and quick lamp tube replacement It can be operated by staff.

5. Standard radiation probe interface is reserved, which can be quickly installed and easily upgraded if needed.


Cooling of the xenon lamp (water cooling):

1 . Chilled pure water flows through the surface of the xenon lamp to create an ideal cooling environment for the lamp tube and maximize the improvement in the life of the xenon lamp.

2. The xenon lamp cooling water fully absorbs the infrared band energy above 1200nm xenon lamp to ensure the authenticity of the test.

3. Add an independent temperature to the cooling water circuit of the xenon lamptemperature probe to prevent poor cooling of the xenon lamp.

4. Set an independent flow rate for the cooling water circuit switch to prevent the cooling water flowing through the xenon lamp from being shut off abnormally.

5. The cooling water circuit is equipped with a high-low, high-sensitivity pressure sensor to avoid abnormal situations Cooling water circuit to ensure required performance.

7 .Humanized design of structural parts, easy and quick lamp tube replacement, no need for manpower operation.

7. margin: 5px 0px;>8. Original French Taikang compressor, additional provision of a test box Temperature and humidity regulate the cooling power requiredd at the same time ensure that the cooling water flowing through the xenon lamp is well cooled.

9. No additional chiller or water tower is required, and installation is simple, fast, and reduces customer's initial investment.