النشرة الإخبارية 40 cubic room with constant temperature and humidity

40 cubic spaces with constant temperature and humidity are often used used in large or A variety of industrial products such as electronics, optoelectronics, electrical appliances, automobiles, LED lights, rubber, photovoltaic, plastics, semiconductors, aerospace and communication equipment are tested for low temperature resistance. To assess whether the parameters such as reliability and stability of the tested product are qualified.


40 cubic space with constant temperature and humidity simple parameters :

temperature and humidity regulation

Type: Balanced temperature and humidity control (BTHC) Intelligent PID adjustment (with Korean or Japanese full-touch controller , which can be switched between Chinese and English )

System: Balanced temperature adjustment and debugging system

Optional custom temperature range: A: 0 ℃ ~ 80 ℃ (100℃); B: -20℃~80℃(100℃); C: -40℃~80℃(100℃); -60℃~80℃(100℃); -70℃~~80℃(100℃);

Custom volume size can be selected : Width, height and depth can be determined at will by the user, and the volume is obtained from the dimensions of width, height and depth. There are 2 to 100 cubic meters to choose from.

Humidity range: 20%-95%R.H (Humidification function is required, you don't need it, or you can run the high and low temperature test function without humidification if you want background-color: =>Uniformity in temperature and humidity chamber: ±2℃;±4.0%RH

Temperature and humidity control accuracy: ±0.2℃;±2.5%RH

Temperature variation: ±0.5℃

Controller Analysis Accuracy: 0.01%℃;±1%RH 20℃ to 100℃ (Within 60 minutes)< /p>

cooling rate: 20°C to -70°C, -60°C, -40°C, -20°C, 0°C (withinof 100 or 90 or 60 or 40 or 30 minutes)

material of the inner body: stainless steel SUS304

shell material: plastic steel plate

Insulation material: ultrafine glass wool + polyurethane foam

Cooling method: mechanical binary cooling method

Refrigerator: Hermetic (French Taikang or German Copeland) Compressor

Refrigerant: R404A < /p>

Condensation method: air-cooled or water-cooled

Safety configuration: no-fuse circuit breaker, compressor over pressure, overheat, overheat current protection, fan overload protection, dry heating protection, low water protection;

Default configuration: 1 thermal insulation peeling observation window, 1 lead hole line, 1 lighting set, indicator light;

Humidity of working environment: 5℃-+35℃; Power supply: AC380±10% 50HZ three-phase, four-wire + protective earth. Also, prepare a water source interface because water is used for humidity.