Large high-temperature aging room in Shandong is also called step-in Type high and low temperature laboratory designated, in equipment with a large test space, suitable for large-scale or large-scale product customization. Especially suitable for: aerospace, aviation, military, communications, electronics, electrical appliances, automobiles, optoelectronics, petroleum, chemical, medical, pharmaceutical, machinery, colleges, scientific research units and other fields.
■ studio volume: 5, 10, 20, 50, 100 cubic meters (optional)
temperature range: normal temperature~80℃
Humidity range: 20 ~ 98% RH
■ Temperature uniformity: ≤2
temperature accuracy: ±0.1℃
■ Heating and cooling rate: 0.7~1℃/min (3℃/min, 5℃/min, 10℃/min)
Outer wall material: high-quality colored sheet steel
■ Base material: SUS304 stainless steel plate
Insulation material: fiberglass cotton/rigid polyurethane foam
Cooling method: Unit Cooling Method/Dual Unit (Cascade) Cooling method
Compressor: French hermetic Taikang refrigeration compressor■ Power supply: 380V 60/50Hz
Controls:
★ The controller is an LCD screen, screen touch setting
★ Programmable function can have 30 patterns × 800 steps × 999 cThe capacity of the cycle, each step 99h59min, 4 sets of timer signal, with RS232C communication interface.
With fixed-point and programmable execution functions, preset start, cold and warm start slope adjustment operating parameters can provide options
★ 10 groups of series programs can be set, and each series has 6 groups of programs.
5 groups of subroutines can be set in each program group to respectively cover the areahs cycle 999 to execute Group Cycle Second rate.
★ Nine error warnings and easy maintenance methods.
★ There is a ∮50mm test hole on the left and right side of the case★ Chinese and English screen display, with RS232 communication interface and Computer online software.
Humidity control system:
● The humidification cylinder is stainless steel with a water level monitoring window attached.
Evaporator coil dew point temperature (ADP) Laminar contact dehumidification method.
● with double protections for overheating and overflow.
● Humidification and dehumidification systems* are independent of each other.
The water level is controlled by a mechanical float valve to prevent electronic malfunction.
Wet water supply Continuous water intake, no recovery Water supply and drainage outside the box is the responsibility of the user.
You can Send Message or email info@qinsun-lab.com to us, we will reply tu you within 24 hours.Now tell us your need,there will be more favorable prices!
Home |
Product |
About |
Contact
Email: info@qinsun-lab.com
No. 2578 Gu Dai Road, Shanghai