We Have More Than 10 Years of Experience.
   
   
top-ban
  1. HOME > News

النشرة الإخبارية large constant temperature laboratory

Large constant temperature laboratories are widely used in large or large-scale industrial products such as electronics, optoelectronics, electrical appliances, automobiles, LED lights, rubber, photovoltaic, plastics, semiconductors, aerospace and communications equipment for low temperature environmental testing. To assess whether the parameters such as reliability and stability of the tested product are qualified.


Simple parameters of a large constant temperature laboratory:

Temperature and humidity control method: Balanced temperature and humidity control method (BTHC) Intelligent PID adjustment ( with Korean or Japanese full-touch controller, which can be switched between Chinese and English ℃ (100 ℃), B: -20°C~80°C (100°C), C: -40°C~80°C (100 °C), -60°C~80°C (100°C ); -70°C~~80°C (100°C) ;

Customized volume size selectable: width, height and depth can by the user at willcan be determined, and the volume is conserved according to the dimensions width, height and depth.

Humidity range: 20% - 95% RH (humidification function may or may not be required, or high and low temperature test function can be performed without humidification if necessary)

Temperature and humidity uniformity the chamber: ±2 °C; ±4.0% relative humidity

Temperature and humidity control accuracy: ±0.2°C; ±2.5%RH

Temperature variation: ±0.5°C

Controller Analysis Accuracy: 0.01%℃, ±1%RH

Heating rate: 20℃ to 100℃ (within 60 minutes)

Cooling rate: 20℃ to -70°C, -60°C, -40°C, -20°C , 0 °C (within 100 or 90 or 60 or 40 or 30 minutes)

Inner body material: SUS304 stainless steel

Shell material: Plastic steel sheet

Insulation material: ultrafine glass wool + polyurethane foam

KCooling method: mechanical binary cooling method

 Refrigerator: hermetic (French Taikang or German Copeland) compressotr

Cooling Medium: R404A

Condensing method: air-cooled or water-cooled

Insurance configuration: no fuse, circuit breaker, compressor overpressure, overheating, overcurrent protection, fan overload protection, dry burn protection, protection from water shortage;

Standard configuration: 1 thermal insulation peel-off viewing window, 1 power cable, 1 set of lighting lamp, indicator light;

Working environment humidity: 5 ° C - + 35 ° C; Power supply: AC380 ± 10% 50Hz three-phase four-wire + protective earth. Also, prepare a water source interface because water is used for humidity.

What Can I Do For You?

You can Send Message or email info@qinsun-lab.com to us, we will reply tu you within 24 hours.Now tell us your need,there will be more favorable prices!

toTop