النشرة الإخبارية UV aging tester

UV aging tester Use UV ultraviolet lamps to simulate the light waves of sunlight, and use condensation and water spray to simulate the climate of dew and rain, and reproduce truly different climates from households, like sunlight , rain and water, material aging or damage caused by extensive weather influences such as high humidity and condensation. To the badTypes of damage include discoloration, discoloration, loss of gloss, cracking, blurring, chalking, cracking, embrittlement, blistering, loss of strength, and oxidation. Widely used in artificial accelerated aging tests of plastics, coatings, paints, rubber materials, glass, decorative plates, aviation, optoelectronic products, industrial fabrics, surface coatings and colored products in simulated environments of sunlight, rain and dew. Used to assess changes in related materials in terms of fading, color change, gloss, cracking, embrittlement, blistering, oxidation, etc. To lay a foundation for improving the material product formula and improving product performance.

UV aging testerTechnical parameters:

Inner Box Size: 1165×450×500mm

Outer box size: 1300×1480 ×550mm

Default instance size : 120mm*50mm, 48 pieces, 75mm*280mm, 24 pieces

Light center distance: 70mm

wavelength range: UV-A wavelength range is 315~400nm

The distance between the test piece and the nearly parallel surface of the lamp surface: about 50mm

Radiation intensity within 1W/m2/340nm

Temperature resolution: 0.01℃

Condensing temperature range: 40℃~60℃/temperature tolerance is ±3℃

Illumination temperature range: 50℃~70℃/temperature tolerance is ±3℃

Measurement range of blackboard thermometer: 30~80℃/Tolerance is ±1℃

Temperature control method:PID Auto-Tuning Temperature Control Method

Humidity range : About 45%~70% RH

Sink requirements: the water depth is not more than 50mm, and there is automatic water supply control

Voltage: 220V ±5%, single-phase, 3-wire, 50Hz, 10A, requires 15A leak switch

Standard Compliant:

1.GB/T16422.3-1997

2.GB/T16585-1996

3.GB/T14522-2008

4.ASTM-D4329 D499 D4587 D5208、G154 G53

5.ISO 4892-3 , ISO 11507,

6.EN534

7.PREN1062-4

8.BS2782

9.JIS D0205

10.SAEJ2020