We Have More Than 10 Years of Experience.
   
   
top-ban
  1. HOME > News

النشرة الإخبارية UV aging tester

UV aging tester Use UV ultraviolet lamps to simulate the light waves of sunlight, and use condensation and water spray to simulate the climate of dew and rain, and reproduce truly different climates from households, like sunlight , Rain and Water, High Humidity, Condensation and other comprehensive climate influences lead .


Material aging or deterioration. Types of damage include discoloration, discoloration, loss of gloss, cracking, blurring, chalking, cracking, embrittlement, blistering, loss of strength, and oxidation. Widely used in artificial accelerated aging tests of plastics, coatings, paints, rubber materials, glass, decorative plates, aviation, optoelectronic products, industrial fabrics, surface coatings and colored products in simulated environments of sunlight, rain and dew Used to detect changes in related materials in terms of fading, color change, Evaluate gloss, cracks, embrittlement, blistering, oxidation, etc. To provide a basis for material product formulation improvement and product performance improvement.

UV aging tester Technical parameters:

Inner box size: 1165×450×500mm

Outer box size: 1300 × 1480 × 550 mm

Standard test piece size: 120 mm x 50 mm, 48 pieces, 75 mm x 280 mm, 24 pieces

Light center distance: 70mm

wavelength range: UV-A wavelength range is 315~400nm

The distance between the test piece and the almost parallel surface of the lamp face: approx. 50mm

Radiation Intensity 1W/ m2/ Within 340nm

Temperature resolution : 0.01℃

Condensing temperature range : 40℃~60℃/temperature tolerance is ±3℃

Lighting temperature range: 50℃~70℃/ The temperature tolerance is ±3℃

Black panel thermometer measurement range: 30~80℃/tolerance is ±1℃

Temperature control method: PID self-tuning temperature control method

Humidity range: Approximately 45% to 70% relative humidity

Sink requirements: the water depth is not greater than 50mm, and there is automatic water supply control

Recommended instrument usage environment: 5~35℃, 40%~85%R•H, 300mm from the wall

Voltage: 220V±5%, single-phase, threecored, 50Hz, 10A, requires 15A leak switch

Standards:

1.GB/T16422 .3- 1997

2.GB/T16585-1996

3.GB/T14522-2008

4.ASTM-D4329 D499 D4587 D5208、G154 G53

5.ISO 4892-3, ISO 11507,

6.EN534

7.PREN1062-4

8.BS2782

9.JIS D0205

10.SAEJ2020

What Can I Do For You?

You can Send Message or email info@qinsun-lab.com to us, we will reply tu you within 24 hours.Now tell us your need,there will be more favorable prices!

toTop