2023-02-27
Helmet Ultraviolet Aging Chamber Use special imported UV lamps to simulate the light waves of sunlight, and use condensation and water spray to simulate the climate of dew and rain and the differences Really reproducible between households Material aging or damage from a wide range of weather conditions such as exposure to sunlight, drizzle, high humidity and condensation. Types of damage include discoloration, fading, loss of gloss, chalking, cracking, cracking, smearing, blistering, embrittlement, loss of strength, and oxidation. Widely used in helmets, paints, coatings, outdoor color advertising, inks, dyes, textiles, automotive interior and exterior parts, plastics, printing and packaging and other industries. The tested material is tested in a cyclic environmental program that alternates between different climate zones. Dangers that last for months to yearse occur outdoors can be reproduced immediately with short test times. Types of hazards include: fading, cracking, clouding, blistering, discoloration, loss of gloss, chalking, embrittlement, loss of strength, and oxidation.
UV aging box for helmetchoice
LQ-UV1 is single function, only separate UV light Function.
LQ-UV3-A is a
LQ-UV3-B also has three functions, but the specifications differ from standard cuts. Thissuitable for placing products with non-standard sizes and irregular sizes that cannot be cut. The LQ-UV3 -A is the same, but the place where the product is placed, is different. It adopts a compartment rack style, suitable for irregular products.
Technical parameters:
Studio size: 450×1170×500mm;
Effective irradiation area: 450×1170×500㎜;
Housing dimensions : 580×1280×1350mm;
Humidity range: ≧95%RH;
Temperature range: RT+10℃~70℃;
Humidity uniformity: ≦±2%;
Temperature Uniformity: ≦±3℃;
TemperatureTemperature Fluctuation: ≦±0.5℃;
Humidity Fluctuation: ≦±2% ;
Lamp center distance: 70㎜;
Sample and lamp center distance: 50㎜;
Standard sample size: 75×285㎜;
Test time : 0~999H adjustable;
Condensing Temperature: 40℃~65℃;
Ultraviolet light and condensation time can be set alternately;
Power supply: AC220V50Hz
Power: 3.5KW
Standard : GB/ T14522-93/GB/T16585-1996 /GB/T16422.3-1997
>You can Send Message or email info@qinsun-lab.com to us, we will reply tu you within 24 hours.Now tell us your need,there will be more favorable prices!
Home |
Product |
About |
Contact
Email: info@qinsun-lab.com
No. 2578 Gu Dai Road, Shanghai
Copyright © 2021.Qinsun Instruments Co., Ltd. All rights reserved.Sitemap