How to correctly choose the constant temperature and thermostat suitable for the experiment

    2022-02-25

    How to correctly choose the constant temperature constant temperature tank to determine the industry in which the constant temperature and humidity box user is located, the constant temperature and humidity box is generally used in the following industries: 1 pharmaceutical factory 2 food factory 3 cosmetics 4 Textile industry 5 college College. (Qinsun Instrument Tips: Pharmaceutical Plant users can choose more professional and targeted drug stability test chambers) 2 Determine the two major parameters requirements for experiments to control: 1 temperature range; 2 humidity range; 3 control wet mode to help Everyone chooses the constant temperature incubator that is suitable for yourself: 1. Temperature range: The thermostat is considered from the experiment and sample, and the temperature range is broader than the drug stability test chamber mentioned before. So, when we select the cabinet, first confirm the temperature range you need, then select the device, according to the Qinsun instrument, usually we see the temperature range below minus, there is also from room temperature, for example: 10 ~ 100 ° C; -40 ~ 100 ° C; RT + 10 ~ 85 ° C, and the like. 2. Humidity range: Similarly, the constant temperature and humidity box is considered from the experiment and sample, and the general humidity range is between: 45 ~ 95% RH, and there will be a small range of requirements, such as 60 ~ 85% RH, The Qinsun instrument reminds everyone that before we choose a constant temperature and humidity box, what is the temperature that needs to be used during his experiment? At this temperature, how much humidity is to be controlled, and you can determine a few common temperature and humidity points, then choose the constant temperature and humidity tank used by the right yourself, so you can choose the most suitable for you, and save costs, don't Don't use the price to measure the constant temperature and humidity box, otherwise it is likely to buy a product that is not suitable for yourself. After determining the humidity range, it is necessary to pay more attention to the consolidation of the constant temperature and humidity tank provided by the manufacturer. How much, better in plusmn; 3% RH, if it is not very good, reach plusmn; 5% RH above, this gap, the effect of doing experiments, can be underestimated. 3. Convection mode: Different to control wet methods can help you determine the accuracy of the experiment to sustainable time and humidity, and now there is a relatively common moisture and humidification method to harmaing the wet ball, it is determined that it takes about two weeks to replace the humidity. The other is a humidification method of the humidity sensor. If the manufacturer humidity sensor is selected Lab is better, then the control and wet accuracy will high, the advantage is to avoid the trouble of frequent replacement of wett. 4. Determine the time range of the constant temperature and humidity box, this step is also a point that many of us will ignore. Many times, we start to determine the constant temperature and humidity box after two steps, in fact, due to the constant temperature and humidity box usually and Different drug boxes, it is more suitable for short-term experiments, so we should pay more attention to the time of the constant temperature and humidity box to run continuously. Qinsun instrument is warmly reminded of the constant temperature and humidity tank, and if more than 6 months, qinsuN The instrument gives you a suggestion or choose a drug box. 5. Determine the amount of constant temperature and humidity box. When choosing the box size, the Qinsun instrument reminds you that we usually need to consider two aspects, the first is where the laboratory is placed, this, we need to consider the size of the box and the size of the laboratory size. Relationship, whether the box can enter the laboratory and can be placed in the laboratory. The second is how much space needs the sample of the experiment, which requires us to consider the volume of the box, and now the constant temperature and humidity tank are small to 50L, large to 1000L, or even several cubic laboratory can do, so Don't worry that there is no suitable size, you can assure the size you want.

    6. Determine whether the constant temperature and humidity box requires programming functions constant temperature and humidity box to program the temperature, humidity, time to set a few programs, and the device automatically switches. When we need to control different temperature and humidity points during the experiment, it is necessary to automatically switch after a period of time, it must choose the constant temperature and humidity box with the programming function, otherwise the experiment is no way to continue to run.
TAGS
May You Like:
What Can I Do For You?

You can Send Message or email info@qinsun-lab.com to us, we will reply tu you within 24 hours.Now tell us your need,there will be more favorable prices!

toTop
CHAT